INNOVATION IN COOLING

Data Center Cooling for Cloud, AI, and High Density

Air, liquid, and hybrid cooling solutions for critical workloads, developed by Aligned and applied to ODATA's infrastructure in Latin America, to meet the new demands of cloud, AI, and high-performance computing (HPC).

Generic purple background for ODATA pages.
Data Center Cooling designed for cloud, AI, and HPC.  

Cooling technology for high-density data centers.

AI, cloud, and HPC workloads demand a data center cooling architecture prepared for critical operations. With Aligned's proprietary and patented cooling technologies, ODATA integrates Delta Cube ™ and Delta Flow ™ into its infrastructure in Latin America to deliver thermal, energy, and water efficiency, as well as operational reliability and flexibility.

Air cooling Liquid cooling Hybrid cooling

Delta Cube™ for high-efficiency air cooling.

Delta Cube ™ is a high-efficiency air cooling technology developed to support high-density environments in Latin America. By capturing and removing heat close to its source, the solution contributes to greater thermal efficiency, dynamic adaptation to IT loads, and integration with liquid or hybrid architectures.

50 kW

density per rack

1 %

of fan power over IT load

24 ° C

average room exit temperature

50 +

Patents granted and over 500 patent claims.

Delta Flow™ for liquid cooling in critical workloads. 

Delta Flow ™ expands liquid cooling capabilities for AI, cloud, and HPC workloads, focusing on thermal, energy, and water efficiency. The solution enables the planning of high-density environments with greater thermal precision, operational reliability, and flexibility for future computing demands.

350 kW

rack heat rejection

2 x

Cooling capacity compared to air-cooled only.

18 ° C

average water supply temperature

1000 x

times more efficient at removing heat than air-only cooling systems.

 Delta Cube™ and Delta Flow™ in a hybrid architecture 

Our hybrid architecture combines air and liquid cooling to accommodate different load profiles in data center environments. With Delta Cube™ and Delta Flow™ , ODATA offers a flexible foundation for customers who need to evolve their infrastructure for critical workloads, while maintaining efficiency, reliability, and adaptability to future high-density demands.

600 +

Heat rejection of kW/rack with liquid cooling + ultra-high density air

350 kW

per heat dissipation rack

Delta_Cube020
0

downtime during the transition between liquid and air cooling

50

Patents granted and over 500 patent applications.

 ADAPTABILITY 

Flexible cooling architecture for data centers. 

ODATA's infrastructure in Latin America is designed to support different data center cooling journeys, whether air, liquid, or hybrid models. With Delta Cube ™ and Delta Flow ™, environments can be planned to evolve according to demand, reducing the need for complex restructurings and preserving efficiency and operational continuity.

Pink and blue wave image for page backgrounds
DIFFERENTIALS

Key decision factors

What to consider when choosing a hyperscale infrastructure in Latin America

Cooling systems
Delta Cube™ and Delta Flow™
air and liquid cooling solutions of Aligned Data Centers
ODATA
(an Aligned Data Centers company)
Other Data Center Providers in Latin America
Traditional cooling technologies
Flexible and future-proof design
accept
dismissed
Up to 600 kW/rack heat rejection
accept
dismissed
Closed-loop design, which minimizes water usage.
accept
dismissed
Transition to liquid cooling without major CapEx reforms.
accept
dismissed
Transition to hybrid or liquid cooling without downtime.
accept
dismissed
DISCOVER OUR TECHNOLOGIES

Cooling system prepared for the next generation of Data Centers

The evolution of digital technology demands data center cooling systems prepared for high density, thermal, energy, and water efficiency, as well as operational predictability. With Delta Cube ™ and Delta Flow ™, ODATA integrates technologies developed for critical environments in Latin America, ready for future computing demands.

Aligned Advanced Cooling Lab (2)

Thermal and operational efficiency

Delta Cube™ and Delta Flow™ technologies are designed to capture and remove heat with greater precision within the data center environment. In a closed-loop system, chilled water is continuously recirculated and reused, contributing to water, thermal, and energy efficiency in critical workloads.

Aligned Delta Flow Advanced Cooling Lab (2)

Flexibility for high density

ODATA's hyperscale data center cooling architecture allows for the combination of air, liquid, and hybrid solutions to suit the specific needs of each workload.

ACL_Delta Cube + DeltaFlow side by side (2)

Patented cooling technology

Delta Cube™ and Delta Flow™ are part of Aligned's portfolio of proprietary and patented technologies, integrated into ODATA's infrastructure in Latin America.

DELTA CUBE CUTAWAY VIEW

Innovation recognized by the sector.

Recognized by leading institutions in the Data Center and sustainability sectors, our cooling technologies reinforce the quality of ODATA's delivery in Latin America.

Generic background with purple waves for ODATA pages.

Get more value from every kilowatt.  

Talk to our experts about how ODATA's hyperscale data center cooling solutions can improve AI, cloud, and HPC environments with greater efficiency, reliability, and operational flexibility.